Sign In | Join Free | My enlightcorp.com
China Guangzhou Hengmeida Automation Technology Co., Ltd logo
Guangzhou Hengmeida Automation Technology Co., Ltd
Rapid-response, exceptional results - customized solutions for your business.
Verified Supplier

1 Years

Home > Lighting Control Cabinet >

Custom Low Voltage Lighting Control Boxes - Metal Shell & Schneider Compatible

Guangzhou Hengmeida Automation Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Custom Low Voltage Lighting Control Boxes - Metal Shell & Schneider Compatible

Contact Now

Custom Low Voltage Lighting Control Boxes - Metal Shell & Schneider Compatible
Product Specifications
Attribute Value
IP Rating IP30 IP40 IP54 IP55 IP65 IP66
Application Building Automation
Material Mid Carbon Steel / Carbon Steel / Stainless Steel / Aluminum Steel
Color Silver or Others
Customization Logo printing, size and color customization available
Mounting Type Wall mount, pole mount, free standing
Usage Smart Building, Public Place or Others
Certifications CE
Size Various sizes available
Locking Mechanism Key lock
Finish Powder coated
Shape Rectangular
Features Durable, corrosion-resistant, weatherproof
Product Description

This intelligent lighting control system offers versatile lighting management with dynamic/zone adjustment (manual or auto-triggered), PWM/0-10V dimming, and preset scenes. The system integrates seamlessly with motion/light sensors, building management, security, and fire systems.

Key features include comprehensive energy monitoring, optimized power distribution, and consumption reduction by 30-50% through demand-based control. Remote monitoring and control is enabled via apps/cloud platforms with real-time alerts and data logging capabilities. The system includes overload, short-circuit, and leakage protection, with automatic emergency lighting activation during power outages.

Standard Dimensions
No. Model Width (mm) Height (mm) Depth (mm)
1 AE300*200 300 200 120
2 AE300*200 300 200 155
3 AE300*250 300 250 160
4 AE300*300 300 300 210
5 Horizontal Box AE300*400 300 400 120
6 AE380*380 380 380 210
7 AE400*300 400 300 210
8 Horizontal Box 400*500 400 500 210
9 AE500*400 500 400 210
10 AE500*500 500 500 210
11 Horizontal Box AE500*600 500 600 250
12 AE600*400 600 400 200
13 AE600*500 600 500 210
14 AE600*600 600 600 210
15 AE600*600 600 600 300
16 Horizontal Box AE600*800 600 800 300
17 AE700*500 700 500 250
18 AE700*600 700 600 250
19 AE760*760 760 760 210
20 AE800*600 800 600 250
21 AE800*800 800 800 300
22 AE1000*600 1000 600 250
23 AE1000*800 1000 800 300
24 AE1200*900 1200 900 300
25 Horizontal Box AE750*1000 750 1000 300
26 Custom - - -
IP Grade

IP54 / IP55 / IP65 / IP66

Material Options

Mid Carbon Steel / Carbon Steel / Stainless Steel / Aluminum Steel

Installation Recommendations

1. Electrical Parameters Confirmation

  • Specify rated voltage (e.g., AC 220V/380V, 50/60Hz) and rated current per circuit (common ranges: 5A-30A) clearly to avoid mismatches with lighting systems.
  • Confirm the number of control circuits and whether expansion is needed (max recommended expansion: 18 circuits per cabinet).
  • Clarify intelligent control requirements (e.g., RS485 communication, GPRS remote control, scene preset functions) if applicable.

2. Protection & Material Specifications

  • Select appropriate IP rating based on application environment: IP54 for general indoor use, IP65+ for outdoor/dusty/humid areas .
  • Specify enclosure material (preferred: anti-rust metal) and thickness; note corrosion resistance requirements for coastal or chemical environments.
  • Confirm heat dissipation needs: reserve at least 200mm of space around wall-mounted units for ventilation .

3. Compliance & Certification Requirements

  • Ensure compliance with target market standards: IEC 60439-1, IEC 60529 (international), CE (EU), UL (US), or GB 7251.1 (China) .
  • For explosive hazardous areas, specify explosion-proof grade and comply with GB 50058 or equivalent international standards .
  • Confirm if Schneider-compatible components are required (e.g., circuit breakers, controllers) for brand consistency .

4. Customization Process & Communication

  • Provide detailed installation method requirements: wall-mounted, floor-standing, or recessed .
  • Confirm sample confirmation process: samples will be provided for testing before mass production; no major design changes are allowed after sample approval.
  • Clarify modification deadline: design adjustments must be submitted 7 working days before production to avoid delivery delays.

5. Installation & Maintenance Adaptation

  • Specify labeling needs: multi-language (English/Chinese) labels for switches, indicators, or custom logos.
  • Request maintenance-friendly features (e.g., bypass switches for emergency lighting, easy-access wiring terminals) if required .

Product Tags:

low voltage lighting control box

      

metal shell lighting control cabinet

      

Schneider compatible control box

      
Quality Custom Low Voltage Lighting Control Boxes - Metal Shell & Schneider Compatible for sale

Custom Low Voltage Lighting Control Boxes - Metal Shell & Schneider Compatible Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Hengmeida Automation Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)